AIR CONDITIONING SYSTEM SIZING IN GREATER LONDON

The choice of modern air conditioning units covers domestic, commercial and industrial applications and it can be complicated to pick the right unit for your needs if you don’t have much experience in this field. The key to a trouble-free, long-lasting and energy-efficient HVAC/Heat pump project is careful planning and professional execution of the plan. Air conditioning supply step by step:

  • map requirements for the HVAC system
  • calculate the heat load
  • map site for system installation
  • match the system to meet site requirements, heat load and installation peculiarities
  • estimate the cost of labour and materials required for the installation
  • deliver install and commission your new air conditioning system to meet warranty standards
CONTACT ENGINEER
SURVEY

WELCOME TO ENGINEERS UNITED AIR CONDITIONING DIVISION

DESIGN | SIZING | SUPPLY | INSTALLATION | MAINTENANCE | SERVICE | DISPOSAL

WE LOVE DESIGNING AND SIZING AIR CONDITIONING SYSTEMS

Fujitsu, Mitsubishi Heavy Industries, Daikin, Mitsubishi Electric, Panasonic, Sanyo, Toshiba, LG, Samsung and other air conditioning brands.

  • Toshiba
  • Sanyo
  • Samsung
  • Panasonic
  • Mitsubishi Electric
  • Mitsubishi Heavy Industries
  • LG
  • Daikin
  • Hitachi
  • Fujitsu

AIR CONDITIONING IMPORTANT PARAMETERS

What is COP, EER, Kw and BTU

AIR CONDITIONER COP & EER

COP – coefficient of performance, is the ratio of heating power to the power usage of the system. Simply put if the COP of the air conditioner system is 3.5 then for one kilowatt of energy used by the system, it will produce 3.5 kilowatts of heating. This is not an actual value of heating capacity because the power consumption of the system may be from 0.7 to 4 KW or even higher.

EER – energy efficiency ratio, is the ratio of cooling power to the power usage of the system. Simply put if the EER of the air conditioner system is 5 then for one kilowatt of energy used by the system, it will produce 5 kilowatts of cooling. 

Air conditioner capacity is can be given in a) watt b) kilowatt c) British thermal units

Here are the conversions:

1 watt = 0,001 kilowatt. 1 kilowatt = 1000 watt.

1 watt = 3.412 BTU.  1000 watt = 3412 BTU  3000 watt = 10 236 BTU. 

OUR STANDARD WORKING HOURS

Monday

Office: 9am - 6pm | Service: 10am - 8pm

Tuesday

Office: 9am - 6pm | Service: 10am - 8pm

Wednesday

Office: 9am - 6pm | Service: 10am - 8pm

Thursday

Office: 9am - 6pm | Service: 10am - 8pm

Friday

Office: 9am - 6pm | Service: 10am - 8pm

Saturday

Duty engineer 10am - 8pm

Sunday

Duty engineer 10am - 8pm

Duty engineer is a subject to availability

COMPARE AIR CONDITIONING CONTRACTOR PRICES IN LONDON

48h SERVICE GUARANTEED. COST COVERS ATTENDANCE, TROUBLESHOOTING, PRICING, REPORT & INVOICING.

£120.00
ATTENDANCE WITHIN 48h*
LONDON, BEDS, BUCKS, HERTS
NO VAT
EVERY JOB IS INDIVIDUALLY PRICED
SPARE PARTS CHARGED SEPARATE IF USED
ATTENDANCE ON AGREED DAY - 90%
ATTENDANCE BEFORE AGREED DAY - 9%
ATTENDANCE ONE DAY LATE - 1%
ON THE SPOT FIX RATE 65%
SECOND FIX RATE 34%
THIRD FIX RATE 1%
WARRANTY ON SERVICE 6 MONTHS
RE-CALLS PROVIDED
NEXT DAY ACCESS TO NEW EQUIPMENT
WE USE LEGAL REFRIGERANT
EXCLUDING BANK HOLIDAYS AND WEEKENDS

WHY IT IS IMPORTANT TO CORRECTLY SIZE AN AIR CONDITIONING SYSTEM?

According to Fujitsu, over 50% of the air conditioning installations are incorrectly sized. An undersized air conditioning system will not be able to do the job and cool your premises during the hottest time of the year. Every cowboy air conditioner fitter understands that undersized air conditioning system:

  1. Will not cool the premises to the desired temperature during summer months when the temperature soars
  2. Therefore operate at the peak of the capacity causing premature wear and tear
  3. Cost more in electricity because operating at the peak of the capacity
  4. But the initial purchase cost is lower, thus be more appealing to the customer

To avoid the trap of under-sizing the equipment the cowboy installers simply go for oversized air conditioning units. The problems with oversized equipment are:

  1. The initial purchase cost is higher
  2. Use more in electricity because the motors are bigger
  3. Cost more to repair when they fault because of the bigger compressor, bigger fans and more refrigerant in the system

Air conditioning sizing calculator coming soon.

 

COMMON AIR CONDITIONER EXAMPLES

AIR CONDITIONING SERVICES

WE SERVICE BEDFORDSHIRE, BUCKINGHAMSHIRE, HERTFORDSHIRE AND LONDON

HEAT LOAD AND HEAT GAIN

Heat load is the sum of all heat sources inside of cooled space. These are people and animals in the room as well as the activity in the room. For instance, people cooking or engaged in sports radiate more heat than people chilling on the sofa. Other contributors to a heat load are lighting equipment, appliances, kettle, computers, printers, broadband routers, skybox, PlayStation, and other similar items. 

Heat gain is the heat gained from outside of the cooled space. This is heat introduced by ventilation, infiltration, solar heat gain, and heat conduction. Heat gain of similar size properties can vary significantly depending on the windows sizes, windows orientation, building materials, types of windows, building insulation, and even flora around the building.

AIR CONDITIONING SYSTEM SIZING FOR HOMES AND SMALL OFFICES

The rule of thumb for air conditioning capacity calculations for homes and small offices is 150w per square meter.